HURNER WHITELINE WELDCONTROL 2.0
The handling of a WeldControl machine is simply unique and it enables an approach to welding no other system is able to offer. Either the operator makes use of the assistance of the interactively responding hydraulic and control unit. Or the manual mode is selected to make the joint “by hand”.
In the WeldControl mode the system walks the operator through the process after the pipe parameters were entered or confirmed. This includes monitoring the operator’s inputs and recording the entire process. WeldControl machines do not only provide presets, though; they facilitate the work, e. g., by reducing the pressure automatically when the automode was enabled. Welding reports have all data required by ISO traceability.
In the Manual mode the display screen works as a digital gauge. It displays the welding pressures and heating element temperatures and is a one-stop provider of all data.
AUTOMATIC DATA LOGGING
10,000 welding operations
DATA INPUT
WELDCONTROL MODE:
RFID transponder, scanner or manually
MANUAL MODE:
Manual temperature control
SYSTEM SETTINGS
Automode, manual input of welding parameters, gauge operation (for pressure, temperature)
WELDING MONITORING SYSTEM
Welding pressures, welding times, ambient temperature, memory control, operating temperature, heating element temperature
STANDARD-COMPLIANT ISO 12176 TRACEABILITY
Commission number with 32 alphanumeric characters, ISO-compliant welder ID code, HÜRNER welder ID code, 1st additional (user-defined) data with 20 alphanumeric characters 2nd additional (user-defined) data with 15 alphanumeric characters, ISO-compliant traceability: fitting code, 1st and 2nd pipe codes, pipe length, weather conditions, joint number, installing company, inventory number
WELDING STANDARD
DVS, WIS, SEDIGAS, UNI, and others upon request
DATA OUTPUT
USB port for data transfer as short abstract or extended report in the PDF format to a USB stick or a label tag printer, incl. tag printer menu; transfer also possible in the HÜRNER DataWork format, with powerful download menu with date range selection, commission number selection, and download of all reports in memory
MISCELLANEOUS
Easy switch from WeldControl mode to Manual mode by a dedicated keypress; ViewWeld: viewing reports on the display rather than printed
HYDRAULIC AND CONTROL UNIT
Only one external power supply needed—power to all electronic components is supplied from the hydraulic unit; automatic heating element temperature control pursuant to national standards; hydraulic unit in encased, rugged steel enclosure with a weight of as little as 19.5 kg (up to O.D. 355 mm); max. pressure, up to O.D. 355 mm, 130 bar; O.D. 500 – 630 mm, 150 bar; O.D. 800 – 1600 mm, 220 bar
LANGUAGES
DE, EN, FR, BG, CS, ZH, NL, FI, GR, IT, NO, RO, SK, TR, RU, and others upon request